Four Reasons Why You Should Avoid Ozone Generator Air Purifier

Not only is ozone potentially dangerous to your health, it may not even work at all. Below are four reasons why you should never use an air purifier that produces ozone.

  1. Ozone Generators May Not Work at All
    Some manufacturers suggest that ozone will render nearly every chemical contaminant in the home harmless by producing a chemical reaction. This is incredibly misleading because a thorough review of scientific research has shown that in order for many of the dangerous chemicals found indoors to be eliminated the chemical reaction process may take months or even years.
3500mg/h Ozone Generator Ozone Machine Purifier Air Cleaner Disinfection Clean
3500mg/h Ozone Generator Ozone Machine Purifier Air Cleaner Disinfection Clean
  1. The Chemical Reaction Can Be Dangerous
    Even if ozone generators were proven to be effective at eliminating these chemicals, there are certain side effects everyone must be aware of. Many of the chemicals ozone reacts to results in a variety of harmful by-products. For example, when ozone was mixed with chemicals from new carpet in a laboratory setting, the ozone reduced many of the chemicals but created a variety of dangerous organic chemicals in the air. While the target chemicals were reduced, the dangerous byproducts rendered the process moved.
  2. Ozone Generators Do Not Remove Particulates
    A third factor to consider when looking at ozone generators is that they do not remove particulates such as dust or pollen from the air. This includes the particles which are primarily responsible for allergic reactions. To combat this, some ozone generators include an ionizer which disperses negatively charged ions into the air. In recent analysis’s, this process was found to be less competent in the removal of air-borne molecules of dust, smoke, pollen, and mold spores than HEPA filters and electrostatic precipitators.
  3. It Is Impossible to Predict Exposure Levels
    The EPA notes that it is increasingly difficult to determine the actual concentration of ozone produced by an ozone generator because so many different factors come into play. Concentrations will be higher if more powerful devices used in smaller spaces. Whether or not the interior doors are closed rather than open will affect concentrations as well.

Different peoples have different ideas, in facet Ozone Generator Air Purifier can effectively eliminates virtually cigarette/cigar smoke, pet odors, paint/cleaning fumes, dust, water damage, smoke damage, cooking odors, and other air borne irritants.

The Difference Between a Sterilizer and an Autoclave

A dental sterilizer is any piece of equipment that is used to destroy all living organisms within the chamber through the use of specifically programmed sterilization cycles. By definition, Webster’s defines a sterilizer as a piece of equipment used to destroy microorganisms in or on, usually by bringing to a high temperature with steam, dry heat, or boiling liquid. However, there are a broad range of processes used for sterilizing:

Global Dental Sterilization Instruments Market 2020 Hu-Friedy ...
The Difference Between a Sterilizer and an Autoclave

Dry Heat Sterilization
Gas/Chemical Sterilization
Glass Bead Sterilization
Steam Sterilization
Sterilization With Ultraviolet Radiation

While many say that sterilizers and autoclaves are synonymous, they are more like a tree-sterilizers are the trunk that autoclaves branch out from. A sterilizer is a general term for any equipment that can sterilize.

An autoclave sterilizer is a specific device that sterilizes equipment. The name is a combination of two ancient words: auto- which is Greek for self, and clave-which is Latin for key. When combined the two words mean “self-locking”.

One of the things that sets steam autoclaves apart from other sterilizers is this automatic lock feature. Since an autoclave is a sterilizer, its purpose is like sterilizers-to kill or remove all forms of life on an object’s surface such as bacteria, fungi, viruses, and spores. While autoclaves solely utilize steam to disinfect, sterilizers can use chemicals, high pressure, filtration, irritation, or a combination of these methods to eliminate living organisms.

Not all sterilizers can be autoclaves sterilizers because not every device can withstand the high temperatures needed to kill every organism. If someone was to use a different type of equipment the material could melt and morph making it unusable.

If you are have any problem in choosing dental equipment such as dental face shield and dental safety goggles, you can feel free to contact our customer service.

The most important points when choosing a endodontic motor

FAQ of UV Sterilization Machine Application

How Can UV be Utilized?
Beyond water and surface sterilization, UV can be used as a sterilization technique for other types of disinfection. UV can disinfect the air in isolated spaces, which is particularly beneficial in a hospital setting. Installing UV devices like lamps and lights at the top of rooms and other areas of circulation can disinfect the air as it moves, improving both the air quality and the effectiveness of the UV sterilization.

2020 New Air Purification System UVC Portable Disinfection Lamp With Ozone UV Lamp Ultraviolet Germicidal Light

Air Purification System UVC Portable Disinfection Lamp With Ozone UV Lamp Ultraviolet Germicidal Light

What Type of UV Light is Best?
Most UV sterilization devices such as UV sterilizer cabinet use UV-C light as the source of their disinfecting power. UV-C light is an effective solution for sterilization, which is why it is the most widely used light type. However, it can cause some serious damage as well. UV-C light can penetrate human skin and cause damage or injury to the person using it, if not careful. UV-C light can also cause damage to certain plastics and rubber materials over time.

Where Can UV be Used?
While UV sterilization can be used as a supplemental infection control strategy for almost any situation, such as disinfecting water and work surfaces as mentioned above, the efficiency of the sterilization make other specialized spaces accessible as well.

Why Use UV Sterilization?
UV sterilization is not a new technology, having been discovered in 1879. Discovered to be a useful technology for cleaning infectious spaces, more studies were done to determine the exact beneficial nature of UV for sterilization purposes. Since the 20th century, UV sterilization has been used to disinfect things like water and work surfaces. UV light is a shorter wavelength than visible light, and is able to penetrate and destroy the bodies of viruses and bacteria.

When picking the right UV sterilizing device, the type of light used in the device is the most important factor in determining which device is the right one for your project. Because of its increased efficiency and improved safety, a device like the Far-UV Sterilray™ can be an incredible tool for sterilization and disinfection. For more information about the Far-UV Sterilray™, click the link for our Far-UV Sterilray™ fact sheet.If you are have any problem in choosing sterilization equipment such as dental autoclave sterilizer and dental dry heat sterilizer, you can feel free to contact our customer service.

The most important points when choosing a endodontic motor
Some Basic Knowledge of Dental Handpiece You Should Know

Why does rotary endo obturation system is better?

Currently, there are several rotary endodontic obturation systems in the dental market and all designed with one specific goal in mind – to clean and shape the canal(s). However, several research studies have illustrated that regardless of the type of file used to shape the canal, none are able to contact all the canal walls or surfaces.

YUSENDENT COXO Dental Endo Gutta Percha Obturation Endodontic C Fill Gun CE

YUSENDENT COXO Dental Endo Gutta Percha Obturation Endodontic C Fill Gun CE

Files are generally categorized as:
Radial-ended files
Enable cleaning and shaping but the procedure is slower and safer
Examples include: Profile & K3
Non-radial-ended files
Cut more effectively but can also lead to errors if not properly managed
Examples include: ProTaper, Twisted Files, Endosequence
The most important factor when choosing and utilizing a particular file system is to follow the appropriate technique outlined by the manufacturer and dictated by the design of the file to remove vital or necrotic tissues from the canal spaces. This will optimize the files’ efficiency and minimize damage to the canal and tooth.

Each file system has advantages and disadvantages; the best system is the one you are proficient with and used to handling.

Additionally, clinicians must adhere to the principles of endodontic treatment:
Completely remove infected material from the canal space
Ensure there is a glide-path before using rotary files
Preserve tooth structure while reducing the risk of vertical root fracture in the future
Manage the apical preparation of the canal to avoid transportation or unnecessary enlargement
Carefully clean and shape the canals in furcation areas to decrease furcation involvement
With respect to obturation, there are 3 techniques that are employed.

  1. Warm Vertical Condensation
    This is the most commonly used technique in North America. Nowadays, there are several techniques which originated from the classic Schilder’s technique. (3) This technique requires clinicians to use a heat carrier (e.g. Touch n’ heat; Calamus Duo; Elements, Super Endo α2) as well as injectable gutta-percha (e.g. Obtura II, Calamus, Super Endo β)
  2. Carrier-based techniques
    This is a popular option used to fill canal spaces. Different carrier-based systems use different core materials to deliver gutta-percha to the canals. Currently, carriers made of cross-linked gutta-percha such as Gutta-Core (Tulsa/Dentsply) are available which may be easier to remove from the canal in situations where retreatment is necessary.
  3. Lateral condensation
    In this technique, gutta-percha cones are placed within the canal and finger spreaders are used to place filling material and pack the canal space. There is an increased possibility of vertical root fracture using this procedure if excessive pressure is applied against the canal walls.

At this time, there is no scientific evidence to suggest whether one system is more advantageous over another.

See more:https://www.dentalsalemall.com/category-80-b0-Endo-Equipment.html

How to choose a dental autoclave sterilizer for your dental practice

How to clean dental autoclave in a short time

What should take into consideration when choosing dental xray unit

Also consider the company from which you are buying the equipment. You should choose a company that is experienced in dental X-ray equipment, that can answer your questions, and that can guide you through the process. If you decide to buy certified pre-owned equipment, you may also want to choose a company that may trade-in used equipment that they sell. That way, when you are ready to upgrade in the future, you can continue to use that company.

BLX-5 Portable Dental Digital Handheld Portable X-Ray Machine System

X-ray tube specifications – the main ones are as follows: anode heat storage capacity (directly affects the system’s effectiveness) and focal spot sizes (the smaller the X-ray tube focal spot size, the clearer the image).

• The generator type and power capacity – high-frequency X-ray generators are preferable since they increase X-ray tube operating life providing maximum safety for patients. Taking the generator power capacity into consideration, you should also remember about the X-ray machine type: portable devices’ standard power capacity may be 3, 6, 15, or 30 kW; stationary X-ray machines’ power capacity range on average from 40 kW to 80 kW. Moreover, the more powerful the generator is, the less exposure time it takes, and consequently, the less radiation patients are exposed to. The Philips Practix Convenio portable dental X-ray unit system with 30 kW power capacity and the Siemens Axiom Luminos TF Eco stationary X-ray machine with 65 kW power capacity are excellent options of respective types.

• X-ray tube mounting types – stationary machines have two mounting options: floor-mounted and ceiling-mounted X-ray tubes. Floor-mounted ones are certainly cheaper to install, and do not require specific room dimensions. But if you expect a large patient stream, it would be best to devote some more funds and purchase the ceiling-mounted X-ray tube because it is more reliable and much easier to use. Siemens Multix Top may be regarded as a desktop X-ray machine.

• An X-ray table is an essential part for any stationary machine. There are tables with either fixed or adjustable height. If the table can move vertically, it’s possible to adapt the X-ray system to examine patients with restricted movement capabilities, as well as for patients with serious medical conditions. The maximum load on the X-ray table is an equally important feature. Most systems allow examining patients with a body weight of up to 200 kilograms. However, some manufacturers produce machines with X-ray tables withstanding even 290 kilograms load and higher.

After having practiced dentistry for nearly four decades, I have seen many new types of materials and equipment come to market. I have personally experienced the old adage, “you live and you learn.” Digital radiography is one of my recent discoveries. After having seen the advantages it offers, I wish I had switched years ago.
If you’re new to digital radiography, you might not be sure about where to start when choosing a system to purchase. Here are four things to consider if you’re thinking about making the investment.

Tips on How to Choosing Dental Digital Xray Machine